Purpose: To evaluate the responsiveness of quality of life (QoL) metrics to ocular and systemic events in patients with noninfectious uveitis. Design: Cohort study using randomized controlled trial data. Participants: Patients with active or recently active intermediate, posterior, or panuveitis enrolled in the Multicenter Uveitis Steroid Treatment (MUST) Trial and Follow-up Study. Methods: Data on the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25), EuroQol Questionnaire (EQ-5D), and Short Form Survey Instrument (SF-36) were evaluated semiannually during the first 3 years after randomization. The impact of ocular (e.g., changes in visual acuity [VA], activity status, cataract surgery) and systemic events (e.g., infections requiring treatment) on the 6-month changes in QoL was assessed for each metric using generalized estimating equations. Main Outcome Measures: The primary outcomes were the 6-month changes in vision-related (NEI-VFQ-25) and general health-related (EQ-5D index, SF-36 physical component summary [PCS]) QoL. Results: Changes in VA (adjusted change [a Delta]: 2.70 units per 5 letter change, P < 0.001), implant placement in at least 1 eye (a Delta: 5.50, P < 0.001), cataract surgery (a Delta: 3.01, P = 0.017), and quieting of all eyes active at the beginning of the interval (a Delta: 2.20, P < 0.010) were associated with improvements in the NEI-VFQ-25. Reductions in VA (a Delta: -0.014 per 5 letter decline, P = 0.003), infections requiring a prescription (a Delta: -0.024, P = 0.021), and incident uveitis activity in at least 1 eye (a Delta: -0.023, P = 0.031) were associated with declines in the EQ-5D index. Hospitalization (aD: -2.24, P = 0.019), infections requiring a prescription (a Delta: -1.00, P = 0.024), and vitreous hemorrhage in at least 1 eye (a Delta: -1.92, P = 0.021) were associated with declines in the SF-36 PCS. Declines in VA, initiation in IOP medication, and age were associated with changes in SF-36 PCS; however, the magnitude of the change was less than a single point. Conclusions: The NEI-VFQ-25 was more sensitive to ocular changes than the general QoL metrics but less sensitive to acute systemic events. When performing QoL or cost-effectiveness analyses, it is important to consider the expected outcomes (e. g., ocular vs. systemic) to ensure that the selected measurement is sensitive enough to detect clinically important changes in disease status or effects of treatment. (C) 2020 by the American Academy of Ophthalmology

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available