Comparison of single breath hyperpolarized129Xe MRI with dynamic19F MRI in cystic fibrosis lung disease

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 85, Issue 2, Pages 1028-1038

Publisher

WILEY
DOI: 10.1002/mrm.28457

Keywords

cystic fibrosis; hyperpolarized gas; perflorinated gas imaging; VDP; ventilation defect

Funding

  1. National Institute of Diabetes and Digestive and Kidney Diseases [P30 DK065988, DK108231]
  2. National Center for Advancing Translational Sciences [UL1TR002489]
  3. Cystic Fibrosis Foundation [DONALD14XX0, GORALS19Y5]
  4. Doris Duke Charitable Foundation [2015213]

Ask authors/readers for more resources

In CF subjects, ventilation abnormalities can be identified by both (19)F and (HPXe)-Xe-129 imaging, but these abnormalities are not entirely congruent. (19)F and (HPXe)-Xe-129 imaging provide complementary information that allows for differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.
Purpose To quantitatively compare dynamic(19)F and single breath hyperpolarized(129)Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic(19)F and single breath(129)Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between(19)F early-breath,F-19 maximum-ventilation,Xe-129 low-resolution, and(129)Xe high-resolution images were compared. Dynamic(19)F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between(129)Xe and(19)F. Results VDP values from high-resolution(129)Xe images were greater than from low-resolution images (P= .001), although these values were significantly correlated (r = 0.68,P= .03). Early-breath(19)F VDP and max-vent(19)F VDP also showed significant correlation (r = 0.75,P= .012), with early-breath(19)F VDP values being significantly greater (P< .001). No correlation in VDP values were detected between either(19)F method or high-res(129)Xe images. In addition, the location and volume of ventilation defects were often different when comparing(129)Xe and(19)F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. Conclusion In CF subjects, ventilation abnormalities are identified by both(19)F and (HPXe)-Xe-129 imaging. However, these ventilation abnormalities are not entirely congruent.F-19 and (HPXe)-Xe-129 imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.