4.3 Article

Assessment of holographic microscopy for quantifying marine particle size and concentration

Journal

LIMNOLOGY AND OCEANOGRAPHY-METHODS
Volume 18, Issue 9, Pages 516-530

Publisher

WILEY
DOI: 10.1002/lom3.10379

Keywords

-

Funding

  1. Rhode Island Science and Technology Advisory Council [AWD05225]
  2. NSF [AWD05524, AWD05643]
  3. NASA's PACE mission
  4. National Aeronautics and Space Administration [80NSSC17K0716]
  5. North Atlantic Aerosol and Marine Ecosystems Study through the National Aeronautic and Space Administration (NAAMES) [NNX15AL2G]
  6. National Science Foundation EPSCoR Cooperative Agreement [OIA-1655221]
  7. Schmidt Ocean Institute

Ask authors/readers for more resources

Holographic microscopy has emerged as a tool for in situ imaging of microscopic organisms and other particles in the marine environment: appealing because of the relatively larger sampling volume and simpler optical configuration compared to other imaging systems. However, its quantitative capabilities have so far remained uncertain, in part because hologram reconstruction and image recognition have required manual operation. Here, we assess the quantitative skill of our automated hologram processing pipeline (CCV Pipeline), to evaluate the size and concentration measurements of environmental and cultured assemblages of marine plankton particles, and microspheres. Over 1 million particles, ranging from 10 to 200 mu m in equivalent spherical diameter, imaged by the 4-Deep HoloSea digital inline holographic microscope (DIHM) are analyzed. These measurements were collected in parallel with a FlowCam (FC), Imaging FlowCytobot (IFCB), and manual microscope identification. Once corrections for particle location and nonuniform illumination were developed and applied, the DIHM showed an underestimate in ESD of about 3% to 10%, but successfully reproduced the size spectral slope from environmental samples, and the size distribution of cultures (Dunaliella tertiolecta,Heterosigma akashiwo, andProrocentrum micans) and microspheres. DIHM concentrations (order 1 to 1000 particles ml(-1)) showed a linear agreement (r(2)= 0.73) with the other instruments, but individual comparisons at times had large uncertainty. Overall, we found the DIHM and the CCV Pipeline required extensive manual correction, but once corrected, provided concentration and size estimates comparable to the other imaging systems assessed in this study. Holographic cameras are mechanically simple, autonomous, can operate at very high pressures, and provide a larger sampling volume than comparable lens-based tools. Thus, we anticipate that these characterization efforts will be rewarded with novel discovery in new oceanic environments.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available