4.6 Article

Assessment of SARS-CoV-2 serological tests for the diagnosis of COVID-19 through the evaluation of three immunoassays: Two automated immunoassays (Euroimmun and Abbott) and one rapid lateral flow immunoassay (NG Biotech)

Journal

JOURNAL OF CLINICAL VIROLOGY
Volume 129, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.jcv.2020.104511

Keywords

SARS-CoV-2; COVID-19; Performance; Automated immunoassays; Lateral flow immunoassay

Categories

Funding

  1. NG Biotech Laboratoires

Ask authors/readers for more resources

Background: The emergence of new SARS-CoV-2 has promoted the development of new serological tests that could be complementary to RT-PCR. Nevertheless, the assessment of clinical performances of available tests is urgently required as their use has just been initiated for diagnose. Objectives: The aim of this study was to assess the performance of three immunoassays for the detection of SARS-CoV-2 antibodies. Methods: Two automated immunoassays (Abbott SARS-CoV-2 CLIA IgG and Euroimmun Anti-SARS-CoV-2 ELISA IgG/IgA assays) and one lateral flow immunoassay (LFIA NG-Test (R) IgG-IgM COVID-19) were tested. 293 specimens were analyzed from patients with a positive RT-PCR response, from patients with symptoms consistent with COVID-19 but exhibiting a negative response to the RT-PCR detection test, and from control group specimens. Days since symptoms onset were collected from clinical information sheet associated with respiratory tract samples. Results: Overall sensitivity for IgG was equivalent (around 80 %) for CLIA, ELISA and LFIA. Sensitivity for IgG detection,> 14 days after onset of symptoms, was 100.0 % for all assays. Overall specificity for IgG was greater for CLIA and LFIA (more than 98 %) compared to ELISA (95.8 %). Specificity was significantly different between IgA ELISA (78.9 %) and IgM LFIA (95.8 %) (p < 0.05). The best agreement was observed between CLIA and LFIA assays (97 %; k= 0.936). Conclusion: Excellent sensitivity for IgG detection was obtained> 14 days after onset of symptoms for all immunoassays. Specificity was also excellent for IgG CLIA and IgG LFIA. Our study shows that NG-Test (R) is reliable and accurate for routine use in clinical laboratories.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available