4.2 Article

Calibrated non-contact vibrational harmonics measurement based on self-vibration compensated 2D-PSD with MEMS accelerometer using FFT analysis

Journal

IET SCIENCE MEASUREMENT & TECHNOLOGY
Volume 14, Issue 8, Pages 877-882

Publisher

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-smt.2019.0229

Keywords

frequency-domain analysis; accelerometers; spectral analysis; position control; vibration measurement; calibration; field programmable gate arrays; fast Fourier transforms; mechanical engineering computing; vibration detection sensor; PSD; vibrating target; external vibrations; detected vibration data; self-vibration technique; ADXL-345 three-axis accelerometer; standard Bruel & Kjaer vibration measurement system; piezoelectric accelerometer; K accelerometer; measurement technique; FFT amplitudes; calibrated noncontact vibrational harmonics measurement; MEMS accelerometer; FFT analysis; vibrational harmonics measurement system; position sensitive detector; frequency-domain vibrational analysis; vibration signal; spectral analysis

Funding

  1. ISRO [B.19012/26/2016-II]

Ask authors/readers for more resources

This study presents a novel fast Fourier transform (FFT)-based non-contact vibrational harmonics measurement system using a position sensitive detector (PSD) along with calibration using a piezoelectric accelerometer. Frequency-domain vibrational analysis is required as the changes in machine dynamics are directly related to its failures and could provide more insight into the vibration signal. In this regard, FFT is used for spectral analysis to detect the harmonics in the vibration signal. The novelty of the applied technique for detecting vibrational harmonics lies in its innate contactless nature where the vibration detection sensor i.e. PSD is placed at a particular distance from the vibrating target. Additionally, the parasitic and external vibrations, which might pose unforeseen errors in the detected vibration data, have been nullified by employing a self-vibration technique using an ADXL-345 three-axis accelerometer. The results obtained through PSD have been calibrated via a standard Bruel & Kjaer (B & K) vibration measurement system which uses a piezoelectric accelerometer (B & K accelerometer). The proposed measurement technique is equipped with NI compact RIO-9074 that features a real-time processor and an FPGA. The system was observed to effectively measure the frequency range 5-600 Hz with a maximum relative error of 2% in FFT amplitudes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available