4.3 Article

Impact of passive heat acclimation on markers of kidney function during heat stress

Journal

EXPERIMENTAL PHYSIOLOGY
Volume 106, Issue 1, Pages 269-281

Publisher

WILEY
DOI: 10.1113/EP088637

Keywords

creatinine; hyperthermia; renal; serum; urine

Categories

Funding

  1. Canada Foundation for Innovation [35775]
  2. Gouvernement du Canada [RGPIN2017-04243]
  3. Natural Sciences and Engineering Research Council of Canada

Ask authors/readers for more resources

This study found that passive heat stress does not alter glomerular filtration rate, but heat acclimation can improve urine-concentrating ability and filtration within the glomerulus.
New Findings What is the central question of this study?Does passive heat acclimation alter glomerular filtration rate and urine-concentrating ability in response to passive heat stress? What is the main finding and its importance?Glomerular filtration rate remained unchanged after passive heat stress, and heat acclimation did not alter this response. However, heat acclimation mitigated the reduction in urine-concentrating ability and reduced the incidence of albuminuria in young healthy adults after passive heat stress. Collectively, these results suggest that passive heat acclimation might improve structural integrity and reduce glomerular permeability during passive heat stress. Little is known about the effect of heat acclimation on kidney function during heat stress. The purpose of this study was to determine the impact of passive heat stress and subsequent passive heat acclimation on markers of kidney function. Twelve healthy adults (seven men and five women; 26 +/- 5 years of age; 72.7 +/- 8.6 kg; 172.4 +/- 7.5 cm) underwent passive heat stress before and after a 7 day controlled hyperthermia heat acclimation protocol. The impact of passive heat exposure on urine and serum markers of kidney function was evaluated before and after heat acclimation. Glomerular filtration rate, determined from creatinine clearance, was unchanged with passive heat stress before (pre, 133 +/- 41 ml min(-1); post, 127 +/- 51 ml min(-1);P = 0.99) and after (pre, 129 +/- 46 ml min(-1); post, 130 +/- 36 ml min(-1);P = 0.99) heat acclimation. The urine-to-serum osmolality ratio was reduced after passive heating (P < 0.01), but heat acclimation did not alter this response. In comparison to baseline, free water clearance was greater after passive heating before (pre, -0.86 +/- 0.67 ml min(-1); post, 0.40 +/- 1.01 ml min(-1);P < 0.01) but not after (pre, -0.16 +/- 0.57 ml min(-1); post, 0.76 +/- 1.2 ml min(-1);P = 0.11) heat acclimation. Furthermore, passive heating increased the fractional excretion rate of potassium (P < 0.03) but not sodium (P = 0.13) or chloride (P = 0.20). Lastly, heat acclimation reduced the fractional incidence of albuminuria after passive heating (before, 58 +/- 51%; after, 8 +/- 29%;P = 0.03). Collectively, these results demonstrate that passive heat stress does not alter the glomerular filtration rate. However, heat acclimation might improve urine-concentrating ability and filtration within the glomerulus.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available