4.6 Article

Unraveling the contributions of internal resistance components in two-chamber microbial fuel cells using the electrode potential slope analysis

Journal

ELECTROCHIMICA ACTA
Volume 348, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2020.136291

Keywords

Two-chamber BES; Electrode resistance; Solution resistance; H-cell MFCs

Funding

  1. Environmental Security Technology Certification Program through the US Army Engineer Research and Development Center [W9132T-16-2-0014]

Ask authors/readers for more resources

Two-chamber (H-cell) bioelectrochemical systems (BESs) are one of the most widely used devices in bioelectrochemistry studies, but comparisons of performance have been challenged by differences in reactor architecture. Here we showed that the reactor solution resistance should be calculated using only the tube cross-sectional area and length rather than the electrode spacing (i.e. the solution resistance in the chambers is negligible). This approach was demonstrated using two H-cells (tube cross sectional areas of 4.5 cm(2) or 1.2 cm(2)) and variable electrode areas. The solution resistance (R-Q) calculated from the tube diameter and length was consistent with that measured using electrochemical impedance spectroscopy (EIS), and was similar to 80% of the total internal resistance with electrode areas larger than the tube area. Anode resistance and total power were similar (R-An = 26 +/- 1 Omega to R-An = 34 +/- 1 Omega 0.37 +/- 0.00 mW) when the anode was larger than the tube area (4.5 cm(2)), but the resistance increased (R-An = 431 +/- 229 Omega) when the anode size (0.8 cm(2)) was smaller than the tube. Power and cathode resistance changed more with the size of the cathode (R-Cat = 61 +/- 5 Omega at 9.6 cm(2), to R-Cat = 73 +/- 7 Omega at 4.9 cm(2)), with very high resistance when the cathode was smaller than the tube diameter (R-Cat = 1246 +/- 805 Omega for 0.8 cm(2) cathode). These results demonstrated that internal resistances are relatively insensitive to electrode sizes when the electrodes are larger than the tube area. While it has not been common to report tube geometry in H-cell studies, these dimensions will need to be reported in future studies in order to make practical comparisons of performance among these types of reactors. (C) 2020 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available