4.3 Article

A failure case of P110 steel tubing in CO2flooding well

Journal

ANTI-CORROSION METHODS AND MATERIALS
Volume 67, Issue 5, Pages 453-463

Publisher

EMERALD GROUP PUBLISHING LTD
DOI: 10.1108/ACMM-04-2020-2296

Keywords

Failure analysis; 110 steel; Downhole tubing; Stress corrosion cracking

Funding

  1. National Key Research and Development Program of China [2018YFB0605502]

Ask authors/readers for more resources

Purpose This paper aims to analyze a failure case of a P110 tube in a CO(2)flooding well. Design/methodology/approach The chemical composition, microstructure and mechanical properties of the failed P110 tubing steel were tested, and met the API Spec 5CT standard. The fractures were investigated by scanning electron microscopy and energy dispersive spectroscopy. Findings Fracture was induced by stress corrosion cracking (SCC) and that the stress concentration caused by the mechanical damage played an important role in the failure. The failure case is a SCC failure affected by mechanical damage and galvanic corrosion. Originality/value The effect of the infiltration of groundwater was studied in the failure case. The stress concentration caused by the mechanical damage played an important role in the failure.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available