4.7 Article

Node-Positive Patients Treated with Neoadjuvant Chemotherapy Can Be Spared Axillary Lymph Node Dissection with Wireless Non-Radioactive Localizers

Journal

ANNALS OF SURGICAL ONCOLOGY
Volume 27, Issue 12, Pages 4819-4827

Publisher

SPRINGER
DOI: 10.1245/s10434-020-08902-y

Keywords

Node positive breast cancer; Sentinel lymph node biopsy; Targeted axillary dissection; Neoadjuvant chemotherapy; Lymph node localization

Ask authors/readers for more resources

Background Targeted axillary dissection (TAD) involves sentinel lymph node biopsy (SLNB) and excision of a biopsy-proven node marked by a clip. This study evaluates the feasibility of non-radioactive wireless localizers for targeted excision of clipped axillary lymph nodes. Methods We identified biopsy-proven, node-positive breast cancer patients treated with neoadjuvant therapy (NAT) and TAD from 2016 to 2020, and included those with a clipped node localized using SAVI SCOUT, Magseed, or RFID Tag. Primary outcome measures were (1) successful localization (ultrasound or mammographic-guided placement < 10 mm from target), and (2) retrieval of the clipped node during TAD, documented by specimen radiography or gross visualization. Secondary outcomes included rates of completion axillary lymph node dissection (cALND) and complications. Results Overall, 57 patients were included; 1 (1.8%) patient had no clip visible at the time of localization, and no radiographic confirmation of clip placement at the time of biopsy, and was therefore excluded. In the remaining 56 patients, localization was successful in 53 (94.6%) patients and the clipped node was retrieved during TAD in 51 (91.1%) patients. Twenty-three of 27 (85.2%) ypN0 patients were spared cALND; 3 (11.1%) patients had cALND for failed clipped node retrieval during TAD, and 1 (3.7%) for false-positive frozen section. In patients with TAD alone, the rates of axillary seroma and infection were 20.0% and 8.6%, respectively. Conclusions Wireless non-radioactive localizers are feasible for axillary localization after NAT, with high success rates of retrieving clipped nodes. The lack of signal decay is an advantage of these devices, allowing flexibility in timing of placement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available