4.3 Article

Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by Single Marker

Journal

JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY
Volume 2020, Issue -, Pages -

Publisher

HINDAWI LTD
DOI: 10.1155/2020/7867046

Keywords

-

Funding

  1. Beijing Municipal Education Commission Common Construction Project [2016022]

Ask authors/readers for more resources

A method, quantitative analysis of multicomponents by single marker (QAMS), was established and fully verified based on high-performance liquid chromatography (HPLC) for simultaneous determination of six chromone indicators of Saposhnikoviae Radix (SR). In the present study, cimifugin (C), 5-O-methylvisamminol (V), hamaudol (H), and their corresponding glycosides, prim-O-glucosylcimifugin (GC), 4 '-O-beta-D-glucosyl-5-O-methylvisamminol (GV), and sec-O-glucosylhamaudol (GH), were selected as bioactive constituents and indicators for the quality evaluation of SR. GV was chosen as the unique reference standard, and relative correction factors (RCF) between GV and the other five chromones were calculated. The feasibility of QAMS for the analysis of chromones was investigated by comparing with the traditional external standard method (ESM). Furthermore, the method was proven to have accuracy (96.98%-102.50%), repeatability (RSD <3%), stability (RSD <3%), precision (RSD <3%), and desirable linearity (R-2 >= 0.9999). Subsequently, 55 batches of commercial SR from different regions were determined by QAMS, and their contents were analyzed by principal component analysis (PCA), correlation analysis, and hierarchical cluster analysis (HCA), respectively. Based on the results, a more refined quality standard of commercial SR was proposed: SR was qualified when the total contents of six chromones were greater than 3 mg center dot g(-1). Furthermore, SR could initially be regarded as a superior medicine when it satisfied both conditions at the same time: the total content of GC, C, GV, V, GH, and H was greater than 8 mg center dot g(-1), and the proportion of the total content of C, V, and H was greater than 10%. This study demonstrated that the quality of SR could be successfully evaluated by the developed QAMS method; meanwhile, valuable information was provided for improving the quality standard of SR.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available