4.6 Article

Islands of misfit buildings: Detecting uncharacteristic electricity use behavior using load shape clustering

Journal

BUILDING SIMULATION
Volume 14, Issue 1, Pages 119-130

Publisher

TSINGHUA UNIV PRESS
DOI: 10.1007/s12273-020-0626-1

Keywords

uncharasteristic behaviour; building energy use; building energy benchmarking; building performance rating; primary-use-type analysis; load profile clustering

Funding

  1. Ministry of Education (MOE) of the Republic of Singapore [R296000181133]
  2. National University of Singapore [R296000158646]
  3. Republic of Singapore's National Research Foundation (NRF)

Ask authors/readers for more resources

Many energy performance analysis methods assign buildings a descriptive label known as the primary space usage (PSU) based on assumptions of how spaces will be used, but this may not reflect actual usage. Analyzing electricity consumption behavior using hourly data can help identify potentially mislabeled buildings. Research shows a percentage of buildings may be mislabeled, providing insight into accurate simulation scenarios.
Many energy performance analysis methodologies assign buildings a descriptive label that represents their main activity, often known as the primary space usage (PSU). This attribute comes from the intent of the design team based on assumptions of how the majority of the spaces in the building will be used. In reality, the way a building's occupants use the spaces can be different than what was intended. With the recent growth of hourly electricity meter data from the built environment, there is the opportunity to create unsupervised methods to analyze electricity consumption behavior to understand whether the PSU assigned is accurate. Misclassification or oversimplification of the use of the building is possible using these labels when applied to simulation inputs or benchmarking processes. To work towards accurate characterization of a building's utilization, we propose a modular methodology for identifying potentially mislabeled buildings using distance-based clustering analysis based on hourly electricity consumption data. This method seeks to segment buildings according to their daily behavior and predict which ones are misfits according to their assigned PSU label. This process finds potentially uncharacteristic behavior that could be an indication of mixed-use or a misclassified PSU. Our results on two public data sets, from the Building Data Genome (BDG) Project and Washington DC (DGS), with 507 and 322 buildings respectively, show that 26% and 33% of these buildings are potentially mislabelled based on their load shape behavior. Such information provides a more realistic insight into their true consumption characteristics, enabling more accurate simulation scenarios. Applications of this process and a discussion of limitations and reproducibility are included.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available