4.6 Article

FRNet: an end-to-end feature refinement neural network for medical image segmentation

Journal

VISUAL COMPUTER
Volume 37, Issue 5, Pages 1101-1112

Publisher

SPRINGER
DOI: 10.1007/s00371-020-01855-z

Keywords

Biomedical segmentation; Fully convolutional neural network; Retinal vessel segmentation; Skin lesion segmentation; Feature refinement path

Funding

  1. Nature Science Foundation of Guangdong province [2016A030313520]

Ask authors/readers for more resources

The paper introduces a lightweight end-to-end feature refinement network (FRNet) to address the issue of spatial information loss in medical image segmentation. By incorporating spatial refinement path, semantic refinement path, and feature adaptive fusion block (FAF block), high accuracy is achieved in different tasks without the need for post-processing.
Medical image segmentation is a crucial but challenging task for computer-aided diagnosis. In recent years, fully convolutional network-based methods have been widely applied to medical image segmentation. U-shape-based approaches are one of the most successful structures in this medical field. However, the consecutive down-sampling operations in the encoder lead to the loss of spatial information, which is important for medical image segmentation. In this paper, we present a novel lightweight end-to-end feature refinement network (FRNet) to address this issue. The structure of our model is simple and efficient. Specifically, the network adopts an encoder-decoder network as backbone, where two additional paths, spatial refinement path and semantic refinement path, are applied on the encoder and decoder, respectively, to improve the detailed representation ability and discriminative ability of our model. In addition, we introduce a feature adaptive fusion block (FAF block) that effectively combines features of different depths. The proposed FRNet can be trained in an end-to-end way. We have evaluated our method on three different medical image segmentation tasks. Experimental results show that FRNet has better performance than the state-of-the-art approaches. It achieves a high average accuracy without any post-processing of 0.968 and 0.936 for blood vessel segmentation and skin lesion segmentation, respectively. We further demonstrate that our method can be easily applied to other network structures to improve their performance.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available