4.7 Article

Theoretical and experimental studies on the fire -induced smoke flow in naturally ventilated tunnels with large cross-sectional vertical shafts

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.tust.2020.103359

Keywords

Tunnel fire; Vertical shaft; Air entrainment; Smoke temperature; Back-layering length

Funding

  1. National Key Research and Development Plan [2018YFB2101001]
  2. research program of Shanghai Committee of Science and Technology [16DZ1200600, 15DZ1203803]
  3. Fundamental Research Funds for the Central University
  4. Research Program of State Key Laboratory of Disaster Reduction in Civil Engineering
  5. Zhejiang province [2018C03029]
  6. Taihang Mountian Highway in Hebei province [KT11]
  7. China Scholarship Council

Ask authors/readers for more resources

The study focuses on the fire-induced smoke flow in a naturally ventilated tunnel with large cross-sectional vertical shafts. For the shaft with large cross-section, the smoke is exhausted along four sides of the shaft, in which condition, the complete plug-holing occurs and the fresh air is entrained into the shaft strongly. In this work, studies on the longitudinal smoke temperature rise, smoke mass and heat exhausted as well as air entrainment from the shaft with large cross-section are performed theoretically. A method to predict the maximum smoke temperature rise downstream the shaft and the smoke back-layering length in naturally ventilated tunnel fires is proposed. Meanwhile, a series of small-scale fire tests was carried out by considering heat release rates (HRR) of the fires, shaft heights and adjacent shaft intervals. Experimental results indicate that the smoke back-layering length decreases with the increasing shaft heights, but it seems to be independent of the HRRs that are greater than 25.8 kW employed in the present work. Lastly, the validation of the proposed models is conducted by comparing with experimental results, which indicates that the models predict well the maximum smoke temperature rise on the downstream side of the shaft and the smoke back-layering length for small fires. The present study contributes to a guidance for smoke control in naturally ventilated tunnel fires with vertical shafts.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available