4.4 Article

Initial clinical experience with a powered circular stapler for colorectal anastomosis

Journal

TECHNIQUES IN COLOPROCTOLOGY
Volume 24, Issue 5, Pages 479-486

Publisher

SPRINGER-VERLAG ITALIA SRL
DOI: 10.1007/s10151-020-02162-4

Keywords

Powered EEA; Echelon circular stapler; Colorectal anastomosis; Powered surgical stapler; 3D stapler; Intelligent surgical stapling

Ask authors/readers for more resources

Background The Echelon circular (TM) powered stapler (ECP stapler) obviates the need for manual firing of conventional circular staplers during the construction of a colorectal anastomosis, but has not been evaluated clinically. The aim of this study was to perform a clinical evaluation of this stapler. Methods A retrospective review of the initial clinical experience of a single surgeon using the ECP stapler for left-sided colorectal anastomosis construction during elective colorectal resections for benign and malignant disease was conducted by analyzing results from a prospectively maintained study database. Additionally, four attending colorectal and/or general surgeons who had performed >= 5 colorectal operations with the ECP stapler were invited to complete an anonymous online survey to subjectively assess the user experience with the device. Statistical analysis was conducted using Microsoft Excel Version 15.33. Results Seventeen patients underwent left-sided anastomotic reconstruction using the ECP stapler. All donuts (proximal and distal) were intact. Anastomotic integrity was evaluated using the air-leak test utilizing flexible video sigmoidoscopy. No leaks were observed, although one patient (5.9%) developed a postoperative pelvic abscess. The anonymous survey was completed by all four surgeons. Subjective evaluation of the ECP stapler suggests that the overall stapling quality, overall device ease-of-use, and the overall perception of anastomotic quality as above average when compared to manual 'end-to-end anastomosis' (EEA) stapling devices. Conclusions In an initial clinical evaluation of the ECP stapler, the safety and ease-of-use of the device appears to be satisfactory. Powered stapling and the design of '3D stapling' may provide advantages over manual systems, and may improve the construction quality of left-sided colorectal anastomosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available