4.7 Article

Electrochemical preconcentration coupled with spectroscopic techniques for trace lead analysis in olive oils

Journal

TALANTA
Volume 210, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2019.120667

Keywords

Electrochemical preconcentration; Trace lead; Spectroscopic analysis; Olive oil; Ionic liquid; Experimental design

Funding

  1. MIUR (Rome, Italy) [PRIN 2010AXENJ8]
  2. Programma Operativo Regionale (POR) by Fondo Europeo di Sviluppo Regionale (FESR) 2014-2020, Safe, Smart, Sustainable Food for Health [3S_4H]

Ask authors/readers for more resources

In this paper we present a novel combined electrochemical-spectroscopic approach suitable to monitor trace levels of heavy metals directly in edible oils. The method is based on the electrochemical preconcentration/ extraction of the analyte from the tested real matrix by cathodic deposition onto a Pt working electrode, then transfer and anodic re-oxidation of the metallic deposit to a clean aqueous solution, suitable for the subsequent spectroscopic analysis. The procedure has been here focused to the determination of lead in extra virgin olive oil (EVOO), performed by applying ICP-QMS or GFAAS techniques. To this aim, the EVOO samples were mixed with proper amounts of the room temperature ionic liquid (RTIL) [P-14(,6,6,6)] + [NITf2](-), in order to obtain a non-aqueous supporting electrolyte suitable for the electrodeposition process. The feasibility and performance of the analytical strategy were at first tested in standard solutions of Pb(II) in RTIL, produced by anodic dissolution of lead in the RTIL, as well as in olive oil samples mixed with 0.5 M RTIL and spiked with known amounts of Pb(II). The optimisation of the electrochemical parameters was achieved by applying a D-Optimal Design, properly set up to optimise the efficiency of the deposition and re-oxidation steps, quantitative recovery and measurement time. Finally, the analytical procedure was applied to the determination of Pb content in some Italian EVOOs, without any need of performing mineralization pretreatments. Data obtained with the proposed procedure satisfactorily agree with those achieved by ICP-QMS analysis after microwave digestion, being differences between the two approaches within 10%, with the advantage of reducing to half the pretreatment time, operating at room temperature and avoiding the use of aggressive solvents.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available