4.6 Article

Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva

Journal

SENSORS
Volume 20, Issue 10, Pages -

Publisher

MDPI
DOI: 10.3390/s20102817

Keywords

thiocyanate ion-selective electrodes; potentiometry; thiocyanate in human saliva; ionograms; calix[4]arene

Funding

  1. Polish Ministry of Science and Higher Education [NN 209417939]
  2. Gdansk University of Technology, Gdansk, PL [DS 030893]
  3. Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw PL [TS201]

Ask authors/readers for more resources

A new solid-contact potentiometric ion-selective electrode for the determination of SCN- (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included selection of a plasticizer for the ion-selective membrane composition and type of the electrode material. The study was carried out using ISE with liquid internal electrolyte (LE-ISE) and solid-contact electrodes made of glassy carbon (GC-ISE) and gold rods (Au-ISE). The best parameters were found for GC sensors for which the ion-selective membrane contained chloroparaffin as a plasticizer (S = 59.9 mV/dec, LOD = 1.6 x 10(-6) M). The study of potentiometric selectivity coefficients has shown that the thiocyanate-selective sensor could be applied in biomedical research for determination of SCN- concentration in human saliva. The accuracy of the SCN- determination was verified by testing 59 samples of volunteers' saliva by potentiometric sensors and UV-Vis spectrophotometry as a reference technique. Moreover, SCN- concentrations in the smokers' and non-smokers' saliva were compared. In order to investigate the influence of various factors (sex, health status, taken medications) on the thiocyanate level in the saliva, more extensive studies on a group of 100 volunteers were carried out. Additionally, for a group of 18 volunteers, individual profiles of SCN- concentration in saliva measured on a daily basis for over a month were collected.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available