4.1 Article

Evaluation of Seismic Fragility Analysis of the Mega Sub-Controlled Structural System (MSCSS)

Journal

JOURNAL OF EARTHQUAKE AND TSUNAMI
Volume 14, Issue 6, Pages -

Publisher

WORLD SCIENTIFIC PUBL CO PTE LTD
DOI: 10.1142/S1793431120500256

Keywords

Mega substructure (MSS); mega sub-controlled structure system (MSCSS); seismic fragility assessment; fragility curve; intensity measure (IM); damage measure (DM)

Funding

  1. National Natural Science Foundation of China [51878274]

Ask authors/readers for more resources

The improved mega sub-controlled structure system (MSCSS) significantly reduced the building responses and improved the control effectiveness as compared to conventional mega substructure (MSS). However, since the MSCSS is designed to resist future earthquakes, the seismic risk assessment of the structure remains a significant concern. In this study, the seismic risk analysis of MSCSS is performed to probabilistically compare the building performance and its resistance to future earthquake damage at certain categories of limit states (LSs), which include category one (slight damage, moderate damage, and collapse damage LS) and category two (damage control and collapse prevention). The comparison is realized with the result of the traditional MSS. The probability of exceedance of the above damage LS for a particular ground motion (GM) intensity (i.e. Sa (T1,5%)) is evaluated to assess and compare the vulnerability of these buildings. The evaluation is done through developing fragility curves and relationships for MSCSS and MSS. The result showed that the improved MSCSS has strong seismic resistance ability and provides a better response from a nonlinear analysis result. Furthermore, the fragility curve of moderate and collapse damage LSs indicated that MSCSS requires higher GM intensity to reach a moderate and collapse damage LS than MSS. That means MSCSS is the most stable with a significant difference as compared to its counterpart. This is also true for the second category of LS, that is, damage control and collapse prevention. While at the slight damage LS, both the MSCSS and MSS require approximately the same GM intensity to reach a slight damage LS, as the difference is not significant.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available