4.7 Article

Overvoltage reduction in membrane Bunsen reaction for hydrogen production by using a radiation-grafted cation exchange membrane and porous Au anode

Journal

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 45, Issue 27, Pages 13814-13820

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2020.02.229

Keywords

Membrane Bunsen reaction; Cell overvoltage; Cation exchange membrane; Radiation grafting; Porous anode electrode

Funding

  1. Council for Science, Technology and Innovation (CSTI), Cross-ministerial Strategic Innovation Promotion Program (SIP), energy carrier (Funding agency: JST)

Ask authors/readers for more resources

An electrochemical membrane Bunsen reaction using a cation exchange membrane (CEM) is a key to achieving iodine-sulfur (IS) thermochemical water splitting for the mass-production of hydrogen. In this study, we prepared a radiation-grafted CEM with a high ion exchange capacity (IEC) and a highly-porous Au-electroplated anode, and then used them for the membrane Bunsen reaction to reduce cell overvoltage. The high ionic content of our CEM led to low resistivity for proton transport, while the high porosity of the electrode led to a large effective surface area for anodic SO2 oxidation. The cell overvoltage for the membrane Bunsen reaction was significantly reduced to 0.21 V at 200 mA/cm(2), one-third of that achieved using a commercial CEM and non-porous anode. From the analysis of the current-voltage characteristics, the grafted CEM was demonstrated to play a dominant role in the overvoltage reduction compared to the porous Au anode. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available