4.6 Article

A 7-Channel High-Tc SQUID-Based On-Scalp MEG System

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 67, Issue 5, Pages 1483-1489

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2019.2938688

Keywords

Magnetoencephalography (MEG); on-scalp MEG; high-T-c SQUID; multichannel system

Funding

  1. Knut and Alice Wallenberg Foundation [KAW 2014.0102]
  2. Swedish Research Council [621-2012-3673]
  3. Swedish Childhood Cancer Foundation [MT2014-0007]
  4. Tillvaxtverket via the European Regional Development Fund [20201637]
  5. ATTRACT project - European Commission [777222]
  6. Swedish Infrastructure for Micro- and Nanofabrication (Myfab)

Ask authors/readers for more resources

Objective: To present the technical design and demonstrate the feasibility of a multi-channel on-scalp magnetoencephalography (MEG) system based on high critical temperature (high-Tc) superconducting quantum interference devices (SQUIDs). Methods: We built a liquid nitrogen-cooled cryostat that houses seven YBCO SQUID magnetometers arranged in a dense, head-aligned array with minimal distance to the room-temperature environment for all sensors. We characterize the performance of this 7-channel system in terms of on-scalp MEG utilization and present recordings of spontaneous and evoked brain activity. Results: The center-to-center spacing between adjacent SQUIDs is 12.0 and 13.4 mm and all SQUIDs are in the range of 1-3 mm of the head surface. The cryostat reaches a base temperature of 70 K and stays cold for >16hwith a single 0.9 L filling. The white noise levels of the magnetometers is 50-130 fT/Hz1/2 at 10 Hz and they show low sensor-tosensor feedback flux crosstalk (<0.6%). We demonstrate evoked fields fromauditory stimuli and single-shot sensitivity to alpha modulation from the visual cortex. Conclusion: All seven channels in the system sensitively sample neuromagnetic fields with mm-scale scalp standoff distances. The hold time of the cryostat furthermore is sufficient for a day of recordings. As such, our multi-channel high-Tc SQUID-based system meets the demands of on-scalp MEG. Significance: The system presented here marks the first high-Tc SQUID-based on-scalp MEG system with more than two channels. It enables us to further explore the benefits of on-scalp MEG in future recordings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available