4.7 Article

Deep learning-guided joint attenuation and scatter correction in multitracer neuroimaging studies

Journal

HUMAN BRAIN MAPPING
Volume 41, Issue 13, Pages 3667-3679

Publisher

WILEY
DOI: 10.1002/hbm.25039

Keywords

attenuation correction; deep learning; neuroimaging tracers; PET; quantification

Funding

  1. Swiss National Science Foundation [320030_176052, 320030_182772, 320030_185028, 320030_169876]
  2. Innovative Medicines Initiatives [115952, 115736]
  3. Horizon 2020 [667375]
  4. Swiss National Science Foundation (SNF) [320030_185028, 320030_182772, 320030_176052] Funding Source: Swiss National Science Foundation (SNF)

Ask authors/readers for more resources

PET attenuation correction (AC) on systems lacking CT/transmission scanning, such as dedicated brain PET scanners and hybrid PET/MRI, is challenging. Direct AC in image-space, wherein PET images corrected for attenuation and scatter are synthesized from nonattenuation corrected PET (PET-nonAC) images in an end-to-end fashion using deep learning approaches (DLAC) is evaluated for various radiotracers used in molecular neuroimaging studies. One hundred eighty brain PET scans acquired using F-18-FDG, F-18-DOPA, F-18-Flortaucipir (targeting tau pathology), and F-18-Flutemetamol (targeting amyloid pathology) radiotracers (40 + 5, training/validation + external test, subjects for each radiotracer) were included. The PET data were reconstructed using CT-based AC (CTAC) to generate reference PET-CTAC and without AC to produce PET-nonAC images. A deep convolutional neural network was trained to generate PET attenuation corrected images (PET-DLAC) from PET-nonAC. The quantitative accuracy of this approach was investigated separately for each radiotracer considering the values obtained from PET-CTAC images as reference. A segmented AC map (PET-SegAC) containing soft-tissue and background air was also included in the evaluation. Quantitative analysis of PET images demonstrated superior performance of the DLAC approach compared to SegAC technique for all tracers. Despite the relatively low quantitative bias observed when using the DLAC approach, this approach appears vulnerable to outliers, resulting in noticeable local pseudo uptake and false cold regions. Direct AC in image-space using deep learning demonstrated quantitatively acceptable performance with less than 9% absolute SUV bias for the four different investigated neuroimaging radiotracers. However, this approach is vulnerable to outliers which result in large local quantitative bias.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available