4.4 Article

Outcomes of subcutaneous implantable cardioverter-defibrillator in dialysis patients: Results from the S-ICD post-approval study

Journal

HEART RHYTHM
Volume 17, Issue 9, Pages 1566-1574

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.hrthm.2020.04.036

Keywords

Arrhythmia; Dialysis; End-stage renal disease; Implantable cardioverter-defibrillator; Subcutaneous ICD; Sudden cardiac death; Ventricular arrhythmia

Funding

  1. Boston Scientific

Ask authors/readers for more resources

BACKGROUND Patients with chronic renal disease on hemodialysis (HD) have limited vascular access and are at high risk of bacteremia. The subcutaneous implantable cardioverter-defibrillator (S-ICD) avoids vascular access, so it may be advantageous in this patient population. OBJECTIVE The purpose of this study was to report outcomes of patients with end-stage renal disease enrolled in the multicenter S-ICD post-approval study (PAS). METHODS S-ICD PAS patients were stratified on the basis of the presence (group 1) or absence (group 2) of HD at the time of implantation. Baseline demographic and clinical characteristics were collected. Perioperative and intermediate-term outcomes 365 days postimplantation were compared between the 2 groups. RESULTS There were 220 patients on HD (13.4%) at the time of implantation out of 1637 patients enrolled in the S-ICD PAS. Patients on HD (group 1) were older (57.4 +/- 13.2 years vs 52.5 +/- 15.2 years; P < .0001), more likely to be of African descent (48.6% vs 25.1%; P < .0001), and had lower ejection fraction (28.6% +/- 11.3% vs 32.6% +/- 14.9%; P < .0001) as compared with patients not on HD (group 2). Group 1 had more comorbidities and mortality was higher (17.4% vs 3.7%) than did group 2. The rate of complications calculated using the Kaplan-Meier estimate did not differ between the 2 groups (overall P = .9169), with a 1-year rate of 7.9% and 7.7% for groups 1 and 2, respectively. The rate of appropriate shocks was significantly higher in group 1 (Kaplan-Meier analysis, P = .0003), as was inappropriate shocks (P = .0137). CONCLUSION S-ICD is associated with similar adverse event rates but a higher risk of inappropriate and appropriate therapy in dialysis patients than in nondialysis patients.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available