4.7 Article

Effect of specimen geometry on triaxial compressive response of high-strength concrete

Journal

CONSTRUCTION AND BUILDING MATERIALS
Volume 244, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2020.118348

Keywords

High-strength concrete; Triaxial compression; Size effects; Length-to-diameter ratio (L/D)

Funding

  1. U.S. Army ERDC Basic Research Program [PE 61102]

Ask authors/readers for more resources

The triaxial compressive response of high-strength concrete is needed to understand pressure-dependent material behavior, which is important for modeling extreme loading events. However, nondestructive damage analysis and dynamic triaxial experiments require specimens that are smaller than those typically used for model calibration. Reducing the specimen diameter from 50 mm to 25 mm showed negligible differences in the material response of a high-strength concrete (no coarse aggregate). However, a scalar correction factor is proposed to account for reductions in length-to-diameter ratio (L/D). By isolating size effects, results from experiments with scaled specimens can be implemented for model calibration efforts. Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available