4.6 Article

Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring

Journal

CLINICAL CHEMISTRY AND LABORATORY MEDICINE
Volume 58, Issue 10, Pages 1687-1695

Publisher

WALTER DE GRUYTER GMBH
DOI: 10.1515/cclm-2019-1260

Keywords

dried blood spots; immunosuppressants; microsampling; therapeutic drug monitoring; volumetric absorptive microsampling

Funding

  1. Netherlands Organization for Health Research and Development (ZonMw, The Hague, Netherlands) [836044004]

Ask authors/readers for more resources

Objectives: Monitoring tacrolimus blood concentrations is important for preventing allograft rejection in transplant patients. Our hospital offers dried blood spot (DRS) sampling, giving patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. In this study, both a volumetric absorptive microsampling (VAMS) device and DBS sampling were compared to venous whole blood (WB) sampling. Methods: A total of 130 matched fingerprick VAMS, fingerprick DBS and venous WB samples were obtained from 107 different kidney transplant patients by trained phlebotomists for method comparison using Passing-Bablok regression. Bias was assessed using Bland-Altman. A multidisciplinary team pre-defined an acceptance limit requiring >80% of all matched samples within 15% of the mean of both samples. Sampling quality was evaluated for both VAMS and DBS samples. Results: 32.3% of the VAMS samples and 6.2% of the DBS samples were of insufficient quality, leading to 88 matched samples fit for analysis. Passing-Bablok regression showed a significant difference between VAMS and WB, with a slope of 0.88 (95% CI 0.81-0.97) but not for DBS (slope 1.00; 95% CI 0.95-1.04). Both VAMS (after correction for the slope) and DBS showed no significant bias in Bland-Altman analysis. For VAMS and DBS, the acceptance limit was met for 83.0% and 96.6% of the samples, respectively. Conclusions: VAMS sampling can replace WB sampling for tacrolimus trough concentration monitoring, but VAMS sampling is currently inferior to DBS sampling, both regarding sample quality and agreement with WB tacrolimus concentrations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available