4.8 Article

Fluoro-Photoacoustic Polymeric Renal Reporter for Real-Time Dual Imaging of Acute Kidney Injury

Journal

ADVANCED MATERIALS
Volume 32, Issue 17, Pages -

Publisher

WILEY-V C H VERLAG GMBH
DOI: 10.1002/adma.201908530

Keywords

acute kidney injury; kidney imaging; optical probes; photoacoustic imaging

Funding

  1. Nanyang Technological University [M4081627] Funding Source: Medline
  2. National Natural Science Foundation of China [81901803] Funding Source: Medline
  3. Natural Science Foundation of Jiangsu Province [BK20190811] Funding Source: Medline
  4. Singapore Ministry of Education Academic Research Fund Tier 1 [2019-T1-002-045, 2017-T1-002-134, RG147/17, RG125/19] Funding Source: Medline
  5. Academic Research Fund Tier 2 [MOE2018-T2-2-042] Funding Source: Medline

Ask authors/readers for more resources

Photoacoustic (PA) imaging agents detect disease tissues and biomarkers with increased penetration depth and enhanced spatial resolution relative to traditional optical imaging, and thus hold great promise for clinical applications. However, existing PA imaging agents often encounter the issues of slow body excretion and low-signal specificity, which compromise their capability for in vivo detection. Herein, a fluoro-photoacoustic polymeric renal reporter (FPRR) is synthesized for real-time imaging of drug-induced acute kidney injury (AKI). FPRR simultaneously turns on both near-infrared fluorescence (NIRF) and PA signals in response to an AKI biomarker (gamma-glutamyl transferase) with high sensitivity and specificity. In association with its high renal clearance efficiency (78% at 24 h post-injection), FPRR can detect cisplatin-induced AKI at 24 h post-drug treatment through both real-time imaging and optical urinalysis, which is 48 h earlier than serum biomarker elevation and histological changes. More importantly, the deep-tissue penetration capability of PA imaging results in a signal-to-background ratio that is 2.3-fold higher than NIRF imaging. Thus, the study not only demonstrates the first activatable PA probe for real-time sensitive imaging of kidney function at molecular level, but also highlights the polymeric probe structure with high renal clearance.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available