4.8 Article

Residential water heater cleaning and occurrence of Legionella in Flint, MI

Journal

WATER RESEARCH
Volume 171, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2019.115439

Keywords

Flint; MI; Legionella; Water heater; Sediment; Flushing; Risk factors

Funding

  1. Michigan Department of Environmental Quality (MDEQ)

Ask authors/readers for more resources

After the Federal emergency in Flint, MI was declared in early 2016 in response to elevated lead-in-water and incidence of Legionnaires' disease, concerns arose that contaminants in residential water heaters could continue to contribute to poor quality tap water. Here, a comprehensive field survey of residential water heaters (n = 30) and associated water quality was conducted and the subsequent effects of an aggressive manual water heater clean-out was determined, including draining the tank and removing sediments via brushing and flushing. Before cleaning, inorganics accumulated in the tank sediments did not serve as a source of metals measured at hot water outlets. After cleaning, hardness- (calcium, magnesium, silica) and corrosion-associated inorganics (lead, iron, copper, aluminum, zinc) decreased by 64% in samples from sediment cleanout drain valves. Culturable L. pneumophila was only detected in 1 home (3.3%) prior to cleaning and 2 homes (6.7%) after cleaning, thus quantitative polymerase chain reaction was used to quantify potential effects on unculturable strains despite the limitation of differentiating live and dead cells. After the cleaning protocol, Legionella spp. and L. pneumophila gene numbers decreased or remained non-detectable in 83% and 98% of samples, respectively. Homes with less than 0.4 mg/L influent free chlorine tended to have quantifiable Legionella spp. gene numbers in water entering the home and had elevated L. pneumophila and Legionella spp. gene numbers throughout the home plumbing. Also, Legionella spp. and L. pneumophila gene numbers were highest for water heaters set at or below similar to 42 degrees C and significantly decreased >51 degrees C, consistent with Legionella's preferred temperature range. Examination of the only home that had culturable L. pneumophila both before and after the cleaning protocol revealed that the organism was culturable from several sample locations throughout the home, including in water representative of the water main. Notably, the home was located in close proximity to McLaren Hospital, where an outbreak of Legionnaires disease was reported, and the water heater had a setpoint within the Legionella growth range of 44.2 degrees C. Considering that other factors were more strongly associated with Legionella occurrence and water heater sediment was not detectably mobilizing to tap water, it was concluded that water heater cleaning had some benefits, but was not an overarching factor contributing to possible human health risks. (C) 2020 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available