4.7 Article

The LI-RADS Version 2018 MRI Treatment Response Algorithm: Evaluation of Ablated Hepatocellular Carcinoma

Journal

RADIOLOGY
Volume 294, Issue 2, Pages 320-326

Publisher

RADIOLOGICAL SOC NORTH AMERICA (RSNA)
DOI: 10.1148/radiol.2019191581

Keywords

-

Ask authors/readers for more resources

Background: The Liver Imaging Reporting and Data System (LI-RADS) treatment response algorithm (TRA) is used to assess presumed hepatocellular carcinoma (HCC) after local-regional therapy, but its performance has not been extensively assessed. Purpose: To assess the performance of LI-RADS version 2018 TRA in the evaluation of HCC after ablation. Materials and Methods: In this retrospective study, patients who underwent ablation therapy for presumed HCC followed by liver transplantation between January 2011 and December 2015 at a single tertiary care center were identified. Lesions were categorized as completely (100%) or incompletely (<= 99%) necrotic based on transplant histology. Three radiologists assessed pre- and post-treatment MRI findings using LI-RADS version 2018 and the TRA, respectively. Interreader agreement was assessed by using the Fleiss k test. Performance characteristics for predicting necrosis category based on LI-RADS treatment response (LR-TR) category(viable or nonviable) were calculated by using generalized mixed-effects models to account for clustering by subject. Results: A total of 36 patients (mean age, 58 years +/- 5 [standard deviation]; 32 men) with 53 lesions was included. Interreader agreement for pretreatment LI-RADS category was 0.40 (95% confidence interval [CI]: 0.15, 0.67; P,.01) and was lower than the interreader agreement for TRA category (kappa = 0.71; 95% CI: 0.59, 0.84; P<.01). After accounting for clustering by subject,sensitivity of tumor necrosis across readers ranged from 40% to 77%, and specificity ranged from 85% to 97% when LR-TR equivocal assessments were treated as nonviable. When LR-TR equivocal assessments were treated as viable, sensitivity of tumor necrosis across readers ranged from 81% to 87%, and specificity ranged from 81% to 85% across readers. Six (11%) of 53 treated lesions were LR-TR equivocal by consensus, with most (five of six) incompletely necrotic at histopathology. Conclusion: The Liver Imaging Reporting and Data System treatment response algorithm can be used to predict viable or nonviable hepatocellular carcinoma after ablation. Most ablated lesions rated as treatment response equivocal were incompletely necrotic at histopathology. (C) RSNA, 2019

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available