4.6 Article

Radiation exposure during transjugular intrahepatic portosystemic shunt creation in patients with complete portal vein thrombosis or portal cavernoma

Journal

RADIOLOGIA MEDICA
Volume 125, Issue 7, Pages 609-617

Publisher

SPRINGER-VERLAG ITALIA SRL
DOI: 10.1007/s11547-020-01155-5

Keywords

Ascites; Bleeding; Liver; Cirrhosis

Ask authors/readers for more resources

Background This study aims to evaluate radiation exposure in patients with complete portal vein thrombosis (CPVT) or portal cavernoma (PC) undergoing transjugular intrahepatic portosystemic shunt (TIPS) creation using real-time ultrasound guidance for portal vein targeting. Materials and methods This is a single institution retrospective analysis. Between August 2009 and September 2018, TIPS was attempted in 49 patients with CPVT or PC. Radiation exposure (dose area product [DAP], air KERMA (AK) and fluoroscopy time [FT]), technical success, clinical success, complications and survival were analyzed. Results In total, 29 patients had CPVT and 20 patients had PC. 41/49 patients had cirrhosis. TIPS indications were refractory ascites (n = 25), variceal bleeding (n = 16) and other (n = 8). TIPS was successfully placed in 94% (46/49) of patients via a transjugular approach alone (n = 40), a transjugular/transhepatic approach (n = 5) and a transjugular/transsplenic approach (n = 1). Median DAP was 261 Gy * cm(2) (range 29-950), median AK was 0.2 Gy (range 0.05-0.5), and median FT was 28.2 min (range 7.7-93.7). Mean portosystemic pressure gradient decreased from 16.8x202f; +/- x202f;5.1 mmHg to 7.5x202f; +/- x202f;3.3x202f;mmHg (P < x202f;0.01). There were no major procedural complications. Overall clinical success was achieved in 77% of patients (mean follow-up of 21.1 months). Encephalopathy was observed in 16 patients (34%), grade II-III encephalopathy in 7 patients (15%). TIPS revision was performed in 15 patients (32%). Overall survival rate was 75%. Conclusion In our experience, the use of real-time ultrasound guidance allowed the majority of the TIPS to be performed via a transjugular approach alone with a reasonably low radiation exposure considering the high technical difficulties of the selected cohort of patients with CVPT or PC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available