4.3 Article

Investigation of the radiation shielding capability of xPbO-(50-x)BaO-50B2O3 glass system using Geant4, Fluka, WinXCOM and comparison of data with the experimental data

Journal

PRAMANA-JOURNAL OF PHYSICS
Volume 94, Issue 1, Pages -

Publisher

INDIAN ACAD SCIENCES
DOI: 10.1007/s12043-019-1890-4

Keywords

Photon attenuation; glasses; Geant4; Fluka; WinXCOM

Ask authors/readers for more resources

In this study, mass attenuation coefficient (mu m), transmission fractions (T), effective atomic numbers (Z(eff)) and half-value layer (HVL) of the xPbO-(50 - x)BaO-50B(2)O(3) (where x = 10, 20, 30, 40 mol%) glass system have been determined from the Monte Carlo simulations carried out with Geant4 and Fluka simulation toolkits and WinXCOM database software. The calculated results were compared with the experimentally obtained mu m values of the selected glass in order to validate the Geant4 model of HPGe detector and Fluka model of NaI(Tl) detectors. T, Z(eff) and HVL shielding parameters of the studied glass system indicate that increase of PbO content from 10 to 40% results in a better shielding behaviour thanks to the high atomic number of lead.