4.5 Article

Blood pressure estimation with complexity features from electrocardiogram and photoplethysmogram signals

Journal

OPTICAL AND QUANTUM ELECTRONICS
Volume 52, Issue 3, Pages -

Publisher

SPRINGER
DOI: 10.1007/s11082-020-2260-7

Keywords

Blood pressure (BP); Complexity analysis; Photoplethysmogram (PPG); Electrocardiogram (ECG); Machine learning

Funding

  1. International Doctoral Innovation Centre, Ningbo Education Bureau, Ningbo Science and Technology Bureau
  2. University of Nottingham
  3. UK Engineering and Physical Sciences Research Council [EP/G037345/1, EP/L016362/1]
  4. Optics and Photonics Research Group in the University of Nottingham

Ask authors/readers for more resources

A novel method for the continual, cuff-less estimation of the systolic blood pressure (SBP) and diastolic blood pressure (DBP) values based on signal complexity analysis of the photoplethysmogram (PPG) and the electrocardiogram (ECG) is reported. The proposed framework estimates the blood pressure (BP) values obtained from signals generated from 14 volunteers subjected to a series of exercise routines. Herein, the physiological signals were first pre-processed, followed by the extraction of complexity features from both the PPG and ECG. Subsequently the complexity features were used in regression models (artificial neural network (ANN), support vector machine (SVM) and LASSO) to predict the BP. The performance of the approach was evaluated by calculating the mean absolute error and the standard deviation of the predicted results and compared with the recommendations made by the British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation. Complexity features from the ECG and PPG were investigated independently, along with the combined dataset. It was observed that the complexity features obtained from the combination of ECG and PPG signals resulted to an improved estimation accuracy for the BP. The most accurate DBP result of 5.15 +/- 6.46 mmHg was obtained from ANN model, and SVM generated the most accurate prediction for the SBP which was estimated as 7.33 +/- 9.53 mmHg. Results for DBP fall within recommended performance of the BHS but SBP is outside the range. Although initial results are promising, further improvements are required before the potential of this approach is fully realised.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available