4.6 Article

Spatially guided nonlocal mean approach for denoising of PET images

Journal

MEDICAL PHYSICS
Volume 47, Issue 4, Pages 1656-1669

Publisher

WILEY
DOI: 10.1002/mp.14024

Keywords

curvelet transform; filtering; image quality; nonlocal means; PET

Funding

  1. Swiss National Science Foundation [SNRF 320030_176052]
  2. Swiss Cancer Research Foundation [KFS-3855-02-2016]

Ask authors/readers for more resources

Purpose Nonlocal mean (NLM) filtering proved to be an effective tool for noise reduction in natural and medical imaging. The technique relies on existing redundant information in the input image to discriminate the genuine signal from noise. However, due to the prohibitively long computation time, the search for finding similar information is confined by a predefined search window, which may hamper the performance of this filter. In this work, a spatially guided non local mean (SG-NLM) approach was proposed to overcome this issue. The proposed method was evaluated on whole-body positron emission tomography images presenting with high noise levels, which adversely affect lesion detectability and quantitative accuracy. Methods In the SG-NLM method, as opposed to the conventional NLM method, where a predefined search window is defined to confine exhaustive search for finding similar patterns, the information about similar patterns is extracted from the clustered version (created based on signal intensity levels) of the input image as well as information about prominent edges. The performance of the SG-NLM was evaluated against post-reconstruction NLM, Gaussian, bilateral and BayesShrink Wavelet denoising approaches. A digital phantom containing three small inserts mimicking lesions in the lung, experimental study using the Jaszczak phantom and whole-body PET/CT clinical studies were utilized to assess the performance of abovementioned denoising approaches. Results The SG-NLM method led to a signal-to-noise (SNR) increase from 21.3 (unfiltered PET image) to 30.1 in computer simulations of small lesions while the NLM mean filer resulted in an SNR of 29.4 (P < 0.05). The experimental Jaszczak phantom study demonstrated that the contrast-to-noise ratio (CNR) increased from 11.3 when using the Gaussian filter to 18.6 and 19.5 when using NLM and SG-NLM filters (P < 0.05), respectively. The superior performance of the SG-NLM approach was confirmed by clinical studies where the bias in malignant lesions decreased to -2.3 +/- 1.1% compared to -11.7 +/- 2.4 and -2.9 +/- 1.1 achieved using the Gaussian and NLM methods (P < 0.05), respectively. Conclusions The proposed SG-NLM achieves promising compromise between noise reduction and signal preservation compared to the conventional NLM method. The superior performance of the SG-NLM method was accomplished without adding extra burden to the computational complexity of the conventional NLM filter, which makes it attractive for denoising PET images.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available