4.7 Article

Xpert MTB/RIF Ultra versus Xpert MTB/RIF for the diagnosis of tuberculous meningitis: a prospective, randomised, diagnostic accuracy study

Journal

LANCET INFECTIOUS DISEASES
Volume 20, Issue 3, Pages 299-307

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/S1473-3099(19)30649-8

Keywords

-

Funding

  1. Wellcome Trust
  2. Foundation for Innovative New Diagnostics

Ask authors/readers for more resources

Background Xpert MTB/RIF Ultra (Xpert Ultra) might have higher sensitivity than its predecessor, Xpert MTB/RIF (Xpert), but its role in tuberculous meningitis diagnosis is uncertain. We aimed to compare Xpert Ultra with Xpert for the diagnosis of tuberculous meningitis in HIV-uninfected and HIV-infected adults. Methods In this prospective, randomised, diagnostic accuracy study, adults (>= 16 years) with suspected tuberculous meningitis from a single centre in Vietnam were randomly assigned to cerebrospinal fluid testing by either Xpert Ultra or Xpert at baseline and, if treated for tuberculous meningitis, after 3-4 weeks of treatment. Test performance (sensitivity, specificity, and positive and negative predictive values) was calculated for Xpert Ultra and Xpert and compared against clinical and mycobacterial culture reference standards. Analyses were done for all patients and by HIV status. Findings Between Oct 16, 2017, and Feb 10, 2019, 205 patients were randomly assigned to Xpert Ultra (n=103) or Xpert (n=102). The sensitivities of Xpert Ultra and Xpert for tuberculous meningitis diagnosis against a reference standard of definite, probable, and possible tuberculous meningitis were 47.2% (95% CI 34.4-60.3; 25 of 53 patients) for Xpert Ultra and 39.6% (27.6-53.1; 21 of 53) for Xpert (p=0.56); specificities were 100.0% (95% CI 92.0-100.0; 44 of 44) and 100.0% (92.6-100.0; 48 of 48), respectively. In HIV-negative patients, the sensitivity of Xpert Ultra was 38.9% (24.8-55.1; 14 of 36) versus 22.9% (12.1-39.0; eight of 35) by Xpert (p=0.23). In HIV co-infected patients, the sensitivities were 64.3% (38.8-83.7; nine of 14) for Xpert Ultra and 76.9% (49.7-91.8; ten of 13) for Xpert (p=0.77). Negative predictive values were 61.1% (49.6-71-5) for Xpert Ultra and 60.0% (49.0-70.0) for Xpert. Against a reference standard of mycobacterial culture, sensitivities were 90.9% (72.2-97.5; 20 of 22 patients) for Xpert Ultra and 81.8% (61.5-92.7; 18 of 22) for Xpert (p=0.66); specificities were 93.9% (85.4-97.6; 62 of 66) and 96.9% (89.5-91.2; 63 of 65), respectively. Six (22%) of 27 patients had a positive test by Xpert Ultra after 4 weeks of treatment versus two (9%) of 22 patients by Xpert. Interpretation Xpert Ultra was not statistically superior to Xpert for the diagnosis of tuberculous meningitis in HIV-uninfected and HIV-infected adults. A negative Xpert Ultra or Xpert test does not rule out tuberculous meningitis. New diagnostic strategies are urgently required. Copyright (C) 2020 The Author(s). Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available