4.7 Article

Quantification of PD-L1 Expression with 18F-BMS-986192 PET/CT in Patients with Advanced-Stage Non-Small Cell Lung Cancer

Journal

JOURNAL OF NUCLEAR MEDICINE
Volume 61, Issue 10, Pages 1455-1460

Publisher

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.119.240895

Keywords

PD-L1 expression; PET/CT; kinetic modeling; immune checkpoint inhibitors

Ask authors/readers for more resources

The aim of this work was to quantify the uptake of F-18-BMS-986192, a programmed cell death ligand 1 (PD-L1) adnectin PET tracer, in patients with non-small cell lung cancer. To this end, plasma input kinetic modeling of dynamic tumor uptake data with online arterial blood sampling was performed. In addition, the accuracy of simplified uptake metrics such as SUV was investigated. Methods: Data from a study with F-18-BMS-986192 in patients with advanced-stage non-small cell lung cancer eligible for nivolumab treatment were used if a dynamic scan was available and lesions were present in the field of view of the dynamic scan. After injection of F-18-BMS-986192, a 60-min dynamic PET/CT scan was started, followed by a 30-min whole-body PET/CT scan. Continuous arterial and discrete arterial and venous blood sampling were performed to determine a plasma input function. Tumor time-activity curves were fitted by several plasma input kinetic models. Simplified uptake parameters included tumor-to-blood ratio as well as several SUV measures. Results: Twenty-two tumors in 9 patients were analyzed. The arterial plasma input single-tissue reversible compartment model with fitted blood volume fraction seems to be the most preferred model as it best fitted 11 of 18 tumor time-activity curves. The distribution volume (V-T) ranged from 0.4 to 4.8 mL.cm(-3). Similar values were obtained with an image-derived input function. From the simplified measures, SUV normalized for body weight at 50 and 67 min after injection correlated best with V-T, with an R-2 of more than 0.9. Conclusion: A single-tissue reversible model can be used to quantify tumor uptake of the PD-L1 PET tracer F-18-BMS-986192. SUV at 60 min after injection, normalized for body weight, is an accurate simplified parameter for uptake assessment of baseline studies. To assess its predictive value for response evaluation during programmed cell death protein 1 or PD-L1 immune checkpoint inhibition, further validation of SUV against V-T based on an image-derived input function is recommended.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available