4.7 Article

Improving the airtightness in an existing UK dwelling: The challenges, the measures and their effectiveness

Journal

BUILDING AND ENVIRONMENT
Volume 95, Issue -, Pages 227-239

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2015.08.017

Keywords

Airtightness; Existing dwellings; Energy efficiency; Retrofit; Refurbishment

Funding

  1. E.ON
  2. Research Councils UK Energy Programme [EP/G000387/1]
  3. Engineering and Physical Sciences Research Council [EP/G000387/1] Funding Source: researchfish
  4. EPSRC [EP/G000387/1] Funding Source: UKRI

Ask authors/readers for more resources

Air infiltration, occurring through gaps in the building envelope, can contribute up to one third of total heat losses associated with older UK dwellings [1]. Therefore, reducing the rate of air leakage (i.e. improving air 'tightness') can have a positive effect in terms of decreasing space heating requirements. This study presents an investigation of the effectiveness of airtightness measures applied in a retrofit context to a UK dwelling. A phased programme of refurbishment work was undertaken to a test dwelling at the University of Nottingham campus, UK. Evaluation techniques, including building energy modelling (SAP 2009), air pressurisation tests and thermal imaging, were performed. The study demonstrates that the use of conventional draught-proofing measures can achieve a reduction in air permeability of over 30% when compared with the house base case value of 15.57 m(3)/(h.m(2)) @ 50 Pa. This reduction was only achievable with close attention to installation detail. Further measures of service penetration and floor sealing enabled the air permeability to be reduced to as low as 4.74 m(3)/(h m(2)) @ 50 Pa. Modelling of the test dwelling predicted an initial space heating supply energy requirement of 32,373 kWh, which was reduced to 23,197 kWh by a combination of the air tightness measures, insulation, and system (boiler and ventilation) improvements. Air tightness measures alone contributed to approximately 9% of the predicted total reduction, half of which was due to relatively straight-forward draught-proofing. Other more advanced air tightness measures were considerably more expensive, though cheaper approaches to their application could help reduce payback times. (C) 2015 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available