4.7 Article

Preoperative MRI-Based Radiomic Machine-Learning Nomogram May Accurately Distinguish Between Benign and Malignant Soft-Tissue Lesions: A Two-Center Study

Journal

JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume 52, Issue 3, Pages 873-882

Publisher

WILEY
DOI: 10.1002/jmri.27111

Keywords

magnetic resonance imaging; soft tissue neoplasms; diagnosis; differential

Ask authors/readers for more resources

Background Preoperative differentiation between malignant and benign soft-tissue masses is important for treatment decisions. Purpose/Hypothesis To construct/validate a radiomics-based machine method for differentiation between malignant and benign soft-tissue masses. Study Type Retrospective. Population In all, 206 cases. Field Strength/Sequence The T(1)sequence was acquired with the following range of parameters: relaxation time / echo time (TR/TE), 352-550/2.75-19 msec. The T(2)sequence was acquired with the following parameters: TR/TE, 700-6370/40-120 msec. The data were divided into a 3.0T training cohort, a 1.5T MR validation cohort, and a 3.0T external validationcohort. Assessment Twelve machine-learning methods were trained to establish classification models to predict the likelihood of malignancy of each lesion. The data of 206 cases were separated into a training set (n =69) and two validation sets (n =64, 73, respectively). Statistical Tests 1) Demographic characteristics: a one-way analysis of variance (ANOVA) test was performed for continuous variables as appropriate. The chi(2)test or Fisher's exact test was performed for comparing categorical variables as appropriate. 2) The performance of four feature selection methods (least absolute shrinkage and selection operator [LASSO], Boruta, Recursive feature elimination [RFE, and minimum redundancy maximum relevance [mRMR]) and three classifiers (support vector machine [SVM], generalized linear models [GLM], and random forest [RF]) were compared for selecting the likelihood of malignancy of each lesion. The performance of the radiomics model was assessed using area under the receiver-operating characteristic curve (AUC) and accuracy (ACC) values. Results The LASSO feature method + RF classifier achieved the highest AUC of 0.86 and 0.82 in the two validation cohorts. The nomogram achieved AUCs of 0.96 and 0.88, respectively, in the two validation sets, which was higher than that of the radiomic algorithm in the two validation sets and clinical model of the validation 1 set (0.92, 0.88 respectively). The accuracy, sensitivity, and specificity of the radiomics nomogram were 90.5%, 100%, and 80.6%, respectively, for validation set 1; and 80.8%, 75.8%, and 85.0% for validation set 2. Data Conclusion A machine-learning nomogram based on radiomics was accurate for distinguishing between malignant and benign soft-tissue masses. Evidence Level 3 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2020;52:873-882.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available