4.3 Article

Performance and cutoffs for liver fibrosis staging of a two-dimensional shear wave elastography technique

Journal

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MEG.0000000000001702

Keywords

chronic liver disease; cirrhosis; liver fibrosis; liver steatosis; shear wave dispersion; shear wave elastography; transient elastography; viral hepatitis; viscosity

Funding

  1. Canon Medical Systems (Japan)

Ask authors/readers for more resources

The study demonstrates that the 2-dimensional shear wave elastography technique is accurate in staging liver fibrosis and shows a high correlation with liver fibrosis. Despite a weak correlation with steatosis, shear-wave-speed dispersion is closely associated with liver fibrosis.
Objectives: To assess performance and cutoffs of the 2-dimensional shear wave elastography technique available on the Aplio i800 ultrasound system (Canon Medical Systems, Japan), using transient elastography as reference standard, and to assess the correlation of shear-wave-speed dispersion with liver fibrosis or steatosis. Methods: This was a single-center cross-sectional study. The correlations between values obtained with transient elastography and 2-dimensional-shear wave elastography, and between shear-wave-speed dispersion and fibrosis or steatosis, were assessed with Pearson's r. The diagnostic performance of the 2-dimensional-shear wave elastography for staging significant fibrosis and severe fibrosis compared to transient elastography was assessed using the area under the receiver operating characteristic curve analysis. Results: Three hundred sixty-seven patients (198 males and 169 females) were studied. There was a high correlation between 2-dimensional-shear wave elastography and transient elastography (r = 0.87, P < 0.0001). The area under the receiver operating characteristics of 2-dimensional-shear wave elastography for staging significant fibrosis (F2) and severe fibrosis (F3-F4), respectively, were 0.97 (95% confidence interval, 0.91-0.98) and 0.97 (95% confidence interval, 0.95-0.99). The best cutoffs for significant fibrosis and severe fibrosis, respectively, were > 7 and > 9 kPa. Shear-wave-speed dispersion showed a high correlation with fibrosis (r = 0.85, P < 0.0001), whereas there was a very weak correlation with steatosis. Conclusions: The results of this study show that this 2-dimensional-shear wave elastography technique is accurate for staging liver fibrosis. Shear-wave-speed dispersion is highly correlated with liver fibrosis but not with steatosis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available