4.7 Article

Electrochemiluminescence resonance energy transfer system between nontoxic SnS2 quantum dots and ultrathin Ag@Au nanosheets for chloramphenicol detection

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 392, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2019.123670

Keywords

Electrochemiluminescence energy resonance transfer; SnS2 quantum dots; Ag@Au nanosheets; Chloramphenicol; Immunosensor

Funding

  1. Science Fund from the National Natural Science Foundation of China [21175097, 31772053]
  2. Project of Scientific and Technologic Infrastructure of Suzhou [SZS201207]
  3. Project of State Key Laboratory of Analytical Chemistry for Life Science [SKLACLS1716]
  4. Suzhou Industry, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials [SYG201636]
  5. Priority Academic Program Development of Jiangsu Higher Education Institutions [YX10900212]

Ask authors/readers for more resources

Herein, an efficient electrochemiluminescence energy resonance transfer (ECL-RET) system was first applied in an immunosensor for the detection of chloramphenicol (CAP). SnS2 quantum dots (SnS2 QDs) has an extremely narrow electrochemical emission spectrum, which was used as donor. Compared with conventional quantum dots, toxic-element-free SnS2 QDs exhibit superior environmental friendliness and biocompatibility. Ultrathin Ag@Au nanosheets (Ag@Au NSs) was selected as acceptor due to its excellent structure and controllable UV-vis absorption range. Furthermore, ZnO nanoflowers (ZnO NFs) was employed to modify the electrode surface to provide stable luminescent environment and support more SnS(2 )QDs. Taking these advantages, the absorption spectra of Ag@Au NSs and the ECL emission spectra of SnS2 QDs are highly matched which ensures the occurrence of ECL-RET. When the CAP analyte were absent, Ag@Au NSs was immobilized on the electrode, and its ultrathin thickness effectively shortens the path of ECL-RET to produce the weak ECL intensity. Inversely, CAP analyte would compete with coating antigen for the certain amount of antibody to remove excess Ag@Au NSs and cause relatively high ECL intensity. As a result, the proposed immunosensor performed satisfactory sensitivity with a wide linear range from 0.005 to 1000 ng(-1) and a low detection limit (1.7 pg mL(-1)).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available