4.4 Article

A novel individualized strategy for cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation

Journal

BMC CARDIOVASCULAR DISORDERS
Volume 19, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s12872-019-01295-1

Keywords

Atrial fibrillation; Cryoablation; Catheter ablation; Cryoballoon; Dosing

Funding

  1. Science and Technology Fund of Tianjin Chest Hospital [2018-XKC09]

Ask authors/readers for more resources

Background: The optimal dosage for cryoablation of atrial fibrillation (Cryo-AF) is still unknown. To evaluate the efficacy of an individualized freeze duration, we compared the clinical outcome of patients treated with a time-topulmonary vein isolation (TT-PVI) or temperature-guided ablation protocol to the outcome of patients treated with a conventional ablation protocol. Methods: A total of 164 consecutive patients were included in the study. One method employed was a conventional dosing protocol (at least 2 applications of 180 s each) (the Cryo-AF(Conventional) group n = 84), and the second method had a shorter protocol that was based on the TT-PVI or achievement of - 40 degrees C within 60 s (the Cryo-AF(Dosing) group n = 80) Results: We treated 656 pulmonary veins (PVs) with 1420 cryotherapy applications. The mean number of applications per patient was 8.7 +/- 0.8, with no difference between groups (Cryo-AF(Conventional), 8.7 +/- 0.8 versus Cryo-AF(Dosing),8.6 +/- 0.8; P = 0.359). The Cryo-AF(Dosing) group required significantly less total cryotherapy application time (990.60 +/- 137.77versus 1501.58 +/- 89.60 s; P < 0.001) and left atrial dwell time (69.91 +/- 6.91 versus 86.48 +/- 7.03 min; P < 0.001) than the Cryo-AF(Conventional) group. Additionally, the Cryo-AF(Dosing) group required significantly less total procedure time (95.03 +/- 6.50 versus 112.43 +/- 7.11 min; P < 0.001). We observed acute ATP-induced or spontaneous vein electric reconnections in 13 veins (1.98%) after 20 min. The reconnection rates between the Cryo-AF(Conventional) and Cryo-AF(Dosing) groups were similar in that 2.98 and 0.94% of the initially isolated veins were reconnected, respectively, (P = 0.061). There was no difference in the recurrence rate of free atrial arrhythmia after a 1-year followup, which were 78.75% in the Cryo-AF(Dosing) group versus (78.57%) in the Cryo-AF(Conventional) group ((P = 0.978).) Conclusion: A novel Cryo-AF dosing protocol guided by temperature or the TT-PVI can be used to individualize an ablation strategy. This new protocol can lead to a significant reduction in duration of the procedure, the cryoenergy dosage and the left atrial dwell time. The procedure had equal safety and similar acute and 1-year follow-up outcomes compared to the conventional approach.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available