4.8 Article

Elastic and surgeon friendly electrospun tubes delivering PDGF-BB positively impact tendon rupture healing in a rabbit Achilles tendon model

Journal

BIOMATERIALS
Volume 232, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.biomaterials.2019.119722

Keywords

Electrospinning; PDGF-BB release; Tendon repair; Tendon biomechanics; Tissue engineering

Funding

  1. Hartmann-Muller foundation, Switzerland
  2. Wolfermann-Nageli foundation, Switzerland
  3. Fonds fur Medizinische Forschung der Universitat Zurich
  4. ab medica, Italy

Ask authors/readers for more resources

A major problem after tendon laceration is the low mechanical strength of the repaired tissue. One viable strategy for improving the functional and biomechanical properties of ruptured and repaired tendons is the delivery of growth factors at the injury site. Here, bioactive and reversibly expandable double-layered emulsion and coaxially electrospun tubes made from biodegradable DegraPol (R) (DP) (polyester urethane), delivering platelet-derived growth factor BB (PDGF-BB), are explored as implants to improve tendon healing in a rabbit Achilles tendon full laceration model. In vitro studies showed that both emulsion and coaxially electrospun scaffolds allow sustained delivery of bioactive PDGF-BB with similar release kinetics (150-190 pg PDGF-BB/mg of DP scaffold) over a period of 30 days. In vivo assessment after three weeks showed that PDGF-BB delivery through the bioactive DP tubes increased the tensile strength of the treated tendons 2-fold without additional pro-fibrotic effects, i.e., cell hyperproliferation or increase in alpha-smooth muscle actin expression at the wound site. While no major differences in ECM composition at the wound site were observed for +/- PDGF-BB treated samples, collagen I and III were upregulated and fibronectin was downregulated compared to native tendons. In areas away from the wound, increased fibronectin expression was observed qualitatively in regions with lower collagen I and III expression. Both types of bioactive DP tubes provided surgeon-friendly and stable implants to deliver bioactive molecules and positively affected the strength of the repaired tendons after 3 weeks, thus presenting promising bioactive implants for clinical applications in the tendon repair field.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available