4.7 Article

Comparative analysis of conventional and low-GWP refrigerants with ionic liquid used for compression-assisted absorption cooling cycles

Journal

APPLIED THERMAL ENGINEERING
Volume 172, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2020.115145

Keywords

Renewable cooling; Waste cooling; Low global warming potential; Novel working pair; Ionic liquid; Compression-assisted absorption cycle

Funding

  1. Research Grants Council of Hong Kong [CityU 21201119]
  2. Guangdong Basic and Applied Basic Research Foundation [2019A1515011177]

Ask authors/readers for more resources

To address the problems of conventional absorption technologies, various working pairs consisting of low-global-warming-potential hydrofluorocarbons/hydrofluoroolefins and ionic liquid were numerically investigated for two compression-assisted absorption cooling cycles driven by heat sources at lower temperatures. The property prediction model and thermodynamic performance model were established and verified. The performance improvements were evaluated and the compression ratio was optimized. With the compression-assisted absorption cycle, the coefficient of performance (COP) was enhanced from 0.191-0.463 to 0.366-0.670, while the minimum generation temperature was reduced by about 20 degrees C, reaching 45 degrees C. For both basic and compression-assisted absorption cycles, difluoromethane yielded the highest COP, followed by fluoroethane and 1,1-difluoroethane with slightly lower COPs; 2,3,3,3-tetrafluoropropene performed the worst in most conditions; 1,1,1,2-tetrafluoroethane performed worse than trans-1,3,3,3-tetrafluoropropene using the basic cycle but outperformed trans-1,3,3,3-tetrafluoropropene using the compression-assisted absorption cycle. The thermal COP varies similarly to but higher than the COP, while the mechanical COPs are much higher for all the working pairs, reaching 11-14 (R152a showing the highest) with a CR of 1.5. The mechanical COP decreases dramatically with the compression ratio. For the low-pressure compression-assisted absorption cycle with a generation temperature of 70 degrees C, the optimal compression ratios were 1.9-3.4 with the maximum COPs of 0.546-0.663 and were 1.3-2.2 with the maximum exergy COPs of 0.192-0.289. The low-pressure compression-assisted absorption cycle was better than the high-pressure compression-assisted absorption cycle due to the higher cycle efficiency and lower compressor discharge temperature. This study provides suggestions on the selection of compression-assisted absorption cycles, working pairs and optimal parameters for renewable/waste cooling.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available