4.8 Article

Novel Chemiluminescence Sensor for Thrombin Detection Based on Dual-Aptamer Biorecognition and Mesoporous Silica Encapsulated with Iron Porphyrin

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 12, Issue 5, Pages 5569-5577

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.9b20255

Keywords

dual-aptamer; biorecognition; hematin; chemiluminescence; thrombin

Funding

  1. National Science Foundation for Young Scientists of China [21605094]
  2. Shandong Province Natural Science Institute Joint Fund [ZR2015YL006]
  3. Horizontal Scientific Research Project of China [W15077]

Ask authors/readers for more resources

Thrombin is a marker of blood-related diseases, and its detection is of great significance in the fields of medical and biological research. Herein, a novel chemiluminescence (CL) sensor for thrombin detection was prepared based on dual-aptamer biorecognition and mesoporous silica encapsulated with iron porphyrin. Mesoporous silica encapsulated with hematin by aptamerl (Apt1/hematin/M-SiO2) and magnetic microspheres modified with aptamer2 (Apt2/NH2-MS) were successfully prepared, and the two materials were used to construct a CL sensor to detect thrombin. Primarily, Apt2/NH2-MS is used for pretreatment separation of thrombin samples by the biorecognition effect between the aptamer (Apt2) and target (thrombin). Then, thrombin/Apt2/NH2-MS is again recognized with Apt1 on the surface of Apt1/hematin/M-SiO2 and Apt1/thrombin/Apt2/NH2-MS is formed, so dual-aptamer biorecognition is realized. Meanwhile, the generated Apt1/thrombin/Apt2/NH2-MS makes Apt1 shed off the surface of M-SiO2 and release hematin. The released hematin can catalyze the luminol-H2O2 CL reaction. Therefore, a sandwich-type CL sensor was constructed based on dual-aptamer biorecognition and hematin catalysis for the detection of thrombin. The sensor has a linear range of 7.5 x 10(-15) to 2.5 x 10(-16) mol.L-1 and a detection limit of 2.2 x 10(-15) mol.L-1 and also exhibits excellent selectivity, reproducibility, and stability. The sensor was successfully used for the detection of thrombin in serum samples, which makes it possible to apply the sensor in the detection of thrombin in actual samples.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available