Journal
SCIENTIFIC REPORTS
Volume 9, Issue -, Pages -Publisher
NATURE PUBLISHING GROUP
DOI: 10.1038/s41598-019-52522-w
Keywords
-
Categories
Funding
- Indian Institute of Technology, Hyderabad
- Department of Science and Technology, India (DST-INSPIRE)
Ask authors/readers for more resources
Bio - molecules detection and their quantification with a high precision is essential in modern era of medical diagnostics. In this context, the memristor device which can change its resistance state is a promising technique to sense the bio - molecules. In this work, detection of the Bovine Serum Albumin (BSA) protein using resistive switching memristors based on TiO2 and TiO2 + graphene oxide (GO) is explored. The sensitivity of BSA detection is found to be 4 mg/mL. Both the devices show an excellent bipolar resistive switching with an on/off ratio of 73 and 100 respectively, which essentially demonstrates that the device with GO, distinguishes the resistance states with a high precision. The enhanced performance in the GO inserted device (similar to 650 cycles) is attributed to the prevention of multi-dimensional and random growth of conductive paths.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available