4.8 Article

Early diagnosis of fungal infections using piezomicrogravimetric and electric chemosensors based on polymers molecularly imprinted with D-arabitol

Journal

BIOSENSORS & BIOELECTRONICS
Volume 79, Issue -, Pages 627-635

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2015.12.088

Keywords

Molecularly imprinted polymer (MIP); Polybithiophene; D-arabitol; Quartz crystal resonator (QCR) chemosensor; Extended-gate field-effect transistor (EG-FET); Candidiasis diagnosis

Funding

  1. Polish National Science Centre [2011/N/ST4/03491, 2011/03/D/ST4/02596, 2014/15/B/NZ/01011]

Ask authors/readers for more resources

An elevated concentration of D-arabitol in urine, especially compared to that of L-arabitol or creatinine, is indicative of a fungal infection. For that purpose, we devised, fabricated, and tested chemical sensors determining D-arabitol. These chemosensors comprised the quartz crystal resonator (QCR) or extended gate field-effect transistor (EG-FET) transducers integrated with molecularly imprinted polymer (MIP) film recognition units. To this end, we successfully applied a covalent approach to molecular imprinting, which involved formation of weak reversible covalent bonds between vicinal hydroxyl groups of arabitol and boronic acid substituents of the bithiophene functional monomer used. The MIP films were synthesized and simultaneously deposited on gold electrodes of quartz crystal resonators (Au-QCRs) or Au glass slides by oxidative potentiodynamic electropolymerization. With the QCR and EG-FET chemosensors, the D-arabitol concentration was determined under flow-injection analysis and stagnant-solution binding conditions, respectively. Selectivity with respect to common interferences, and L-arabitol in particular, of the devised chemosensors was superior. Limits of detection and linear dynamic concentration ranges of the QCR and EG-FET chemosensors were 0.15 mM and 0.15 to 1.25 mM as well as 0.12 mM and 0.12 to 1.00 mM, respectively, being lower than the o-arabitol concentrations in urine of patients with invasive candidiasis ( > 220 mu M). Therefore, the devised chemosensors are suitable for early diagnosis of fungal infections caused by Candida sp. yeasts. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available