4.8 Article

Rapid electrical immunoassay of the cardiac biomarker troponin I through dielectrophoretic concentration using imbedded electrodes

Journal

BIOSENSORS & BIOELECTRONICS
Volume 82, Issue -, Pages 78-84

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2016.03.056

Keywords

Cardiovascular disease; Carbon nanotubes; Cardiac troponin I; Dielectrophoresis; Immunoassay

Funding

  1. Basic Science Research Program through National Research Foundation of Korea (NRF), - Ministry of Science, ICT and Future Planning [2015R1A2A2A01006446]
  2. National Research Foundation of Korea [2015R1A2A2A01006446] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

Rapidity and high sensitivity are critical factors for the diagnoses of heart attacks, and cardiac troponin I (cTnI) is at present a clinical standard for its diagnosis. Here we report a rapid, label-free, and highly sensitive single-walled carbon nanotube (SWCNT) electrical immunosensor, featuring two pairs of electrodes. Two concentration electrodes (gaps: 25 and 80 gm) and two detection electrodes (source and drain; gap: 20 gm; width: 50 gm) were used for dielectrophoretic concentration of cTnI on the SWCNT channels and resistance measurements of the dielectrophoresis (DEP)-concentrated cTnI, respectively. The two concentration electrodes were imbedded between upper and lower dielectric layers, facing each other, underneath the -COOH-functionalized SWCNT channels deposited between the detection electrodes. Therefore, the gap between these imbedded concentration electrodes can be reduced to maximize the electric field intensity for DEP-mediated concentration of cTnI, thereby greatly reducing the detection time (1 min) and enhancing the limit of detection (0.7-0.8 pg mL(-1)). Relative resistance changes of the SWCNTs were measured as cTnl concentration in Tris-Borate-EDTA (TBE; 0.0025 x) and human serum diluted 500-fold with 0.0025 x TBE decreased from 100 ng mL(-1) to 1 pg mL(-1), and they were shown to be linear with the logarithm of cTnI concentration (R-2=0.99 and 0.97, respectively). These immunosensors also showed high specificity over another cardiac biomarker, myoglobin, TBE medium (0.0025 x), and 500-fold diluted human serum. The DEP-capture of cTnI depended on the frequency of the applied electric field, demonstrating the qualitative nature of the real part of the Clausius-Mossotti factor for cTnl. (C) 2016 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available