4.1 Article

Quality of life, depression, and anxiety in patients with a subcutaneous versus transvenous defibrillator system

Journal

PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY
Volume 42, Issue 12, Pages 1541-1551

Publisher

WILEY
DOI: 10.1111/pace.13828

Keywords

anxiety; depression; implantable cardioverter defibrillator; quality of life

Funding

  1. Boston Scientific Corporation, St. Paul, Minnesota, USA
  2. VENI grant from the Netherlands Organization for Scientific Research (NWO) [451-05-001]
  3. VIDI grant from the Netherlands Organization for Health Research and Development (ZonMw), the Hague, the Netherlands [91710393]

Ask authors/readers for more resources

Background Use of the subcutaneous implantable defibrillator (S-ICD) has increased because the device received US Food and Drug Administration approval in 2012, but we still know little about whether the quality of life (QoL) of patients with an S-ICD versus a transvenous ICD (TV-ICD) is comparable. We compared S-ICD patients with TV-ICD patients on QoL, depression, and anxiety up to 12 months' follow-up. Methods A matched cohort of S-ICD (N = 167) and TV-ICD patients (N = 167) completed measures on QoL, depression, anxiety, and personality at baseline, 3, 6, and 12 months post implant. Data were analyzed using multivariable modeling with repeated measures. Results In adjusted analyses, we found no statistically significant differences between cohorts on physical and mental QoL and depression (all Ps > .05), while S-ICD patients reported lower anxiety than TV-ICD patients (P = 0.0007). Both cohorts experienced improvements in physical and mental QoL and symptoms of depression and anxiety over time (all Ps < .001), primarily between implant and 3 months. These improvements were similar for both cohorts with respect to physical and mental QoL and anxiety (Ps > .05), while S-ICD patients experienced greater reductions in depressive symptoms (P = .0317). Conclusion The QoL and depression levels were similar in patients with an S-ICD and a TV-ICD up to 12 months' follow-up, while S-ICD patients reported lower anxiety levels and a greater reduction in depression over time as compared to TV-ICD patients. This knowledge may be important for patients and clinicians, if the indication for implantation allows both the S-ICD and the TV-ICD, making a choice possible.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available