4.8 Article

Comparison of energy losses in a 9 kW vanadium redox flow battery

Journal

JOURNAL OF POWER SOURCES
Volume 440, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.jpowsour.2019.227144

Keywords

Vanadium redox flow battery; Species crossover; Shunt currents; Energy losses; Pumping losses; Efficiency

Funding

  1. University of Padua within the Project 2016 of the Interdepartmental Centre Giorgio Levi Cases for Energy Economics and Technology Next-Generation VRFB Energy Storage Systems [GUAR_RICERCALASCITOLEVI17_02]

Ask authors/readers for more resources

An analysis is presented of the losses occurring in a kW-class vanadium redox flow battery due to species crossover, shunt currents, hydraulic pressure drops and pumping, in addition to cell overpotentials. The study was developed on a 9 kW/27 kW h test facility that includes a stack consisting of a 40 cells with 600-cm(2) cross sectional area and two 550 L electrolyte tanks. The analysis was carried out combining experimental data and model results. The losses were evaluated as functions of the solution flow rates at stack currents of 30 A, 50 A and 70 A. Charge-discharge cycles performed at a constant flow factor equal to 8 and thus at variable flow rate were analyzed. Results show that shunt currents have a tenfold to twentyfold higher effect than hydraulic pressure drop inside the stack. As regards cell membranes, it has been found that, in terms of efficiency, the ion conductivity (i.e. cell overpotentials) counts more than species diffusivity (i.e. crossover). Moreover, it was found that pumps and their motors can affect significantly the efficiency of a kW-class vanadium redox flow battery system.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available