4.6 Article

Thermoluminescence and phototransferred thermoluminescence dosimetry on mobile phone protective touchscreen glass

Journal

JOURNAL OF APPLIED PHYSICS
Volume 126, Issue 7, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.5108971

Keywords

-

Funding

  1. state of Oklahoma
  2. Oak Ridge Associated Universities [G10001987]
  3. Stewardship Science Academic Alliances (SSAA) Program of the National Nuclear Security Administration (NNSA) [DE-NA0001983]

Ask authors/readers for more resources

Thermoluminescence and phototransferred thermoluminescence measurements of protective glass from smartphones are described. Samples of Gorilla Glass were examined from nine different manufacturers and 40 different phone models. Additionally, 12 glasses believed to be original equipment manufacturer replacements, as well as three glass samples from U.S. finishers, were also studied. Altogether, 99 different Gorilla Glass samples were examined. The radiation-induced thermoluminescence signal produced glow curve shapes specific to the Gorilla Glass generations and could be used to distinguish between them. A background thermoluminescence (and phototransferred thermoluminescence) signal was found in all unirradiated samples. Its intensity and shape were found to be dependent on the Gorilla Glass generation, phone manufacturer, and phone model. The background signal was demonstrated to be produced by ultraviolet light exposure; the shape of the background signal was able to be reproduced by the combined exposure to a broad-spectrum solar simulator and a 302 nm ultraviolet light source. The background signal intensity was found to vary with the location from which it was taken on the glass. It was also found to be dependent on the depth within the Gorilla Glass due to absorption of the ultraviolet light as it traversed the medium. Removal of the glasses' surface layers was found to be an inadequate method for removing the background signal. In some samples, the background signal intensity was large enough to significantly contribute to the total thermoluminescence (and phototransferred thermoluminescence) signal; therefore, a matrix deconvolution method was introduced to separate the background signal and radiation-induced signal. This method was found to enable dose reconstruction using the radiation-induced signal alone. Published under license by AIP Publishing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available