4.6 Article

Relaxation volumes of microscopic and mesoscopic irradiation-induced defects in tungsten

Journal

JOURNAL OF APPLIED PHYSICS
Volume 126, Issue 7, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.5094852

Keywords

-

Funding

  1. Euratom Research and Training Programme 2019-2020 [633053]
  2. RCUK Energy Programme [EP/P012450/1]
  3. high-performance computing facility MARCONI (Italy) through the EUROfusion HPC project AMPSTANI (2017-2019)
  4. Academy of Finland [311472]
  5. Academy of Finland (AKA) [311472, 311472] Funding Source: Academy of Finland (AKA)
  6. EPSRC [EP/T012250/1] Funding Source: UKRI

Ask authors/readers for more resources

The low-energy structures of irradiation-induced defects in materials have been studied extensively over several decades, as these determine the available modes by which a defect can diffuse or relax, and how the microstructure of an irradiated material evolves as a function of temperature and time. Consequently, many studies concern the relative energies of possible defect structures, and empirical potentials are commonly fitted to or evaluated with respect to these. But recently [S. L. Dudarev et al., Nucl. Fusion 58, 126002 (2018)], we have shown that other parameters of defects not directly related to defect energies, namely, their elastic dipole tensors and relaxation volumes, determine the stresses, strains, and swelling of reactor components under irradiation. These elastic properties of defects have received comparatively little attention. In this study, we compute relaxation volumes of irradiation-induced defects in tungsten using empirical potentials and compare to density functional theory results. Different empirical potentials give different results, but some clear potential-independent trends can be identified. We show that the relaxation volume of a small defect cluster can be predicted to within 10% from its point-defect count. For larger defect clusters, we provide empirical fits as a function of defect cluster size. We demonstrate that the relaxation volume associated with a single primary-damage cascade can be estimated from the primary knock-on atom energy. We conclude that while annihilation of defects invariably reduces the total relaxation volume of the cascade debris, there is still no conclusive verdict about whether coalescence of defects reduces or increases the total relaxation volume. Published under license by AIP Publishing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available