Analysing the effects of cold, normal, and warm digits on transmittance pulse oximetry

Journal

BIOMEDICAL SIGNAL PROCESSING AND CONTROL
Volume 26, Issue -, Pages 34-41

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2015.12.006

Keywords

Pulse oximetry; Non-invasive; Photoplethysmograph; Arterial blood oxygen saturation; Signal processing; Sensor; Thermocouple; Perfusion; Vasoconstriction; Vasodilation

Ask authors/readers for more resources

Non-invasive estimation of arterial oxygen saturation (SpO(2)) and heart rate using pulse oximeters is widely used in hospitals. Pulse oximeters rely on photoplethysmographic (PPG) signals from a peripherally placed optical sensor. However, pulse oximeters can be less accurate if the sensor site is relatively cold. This research investigates the effects on PPG signal quality of local site temperatures for 20 healthy adult volunteers (24.5 +/- 4.1 years of age). Raw PPG data, composed of Infrared (IR) and Red (RD) signals, was obtained from a transmittance finger probe using a custom pulse oximeter (PO) system. Three tests were performed with the subject's hand surface temperature maintained at baseline (29 +/- 2 degrees C), cold (19 +/- 2 degrees C), and warm (33 +/- 2 degrees C) conditions. Median root mean square (RMS) of PPG signal during the Cold test dropped by 54.0% for IR and 30.6% for RD from the baseline values. In contrast, the PPG RMS increased by 64.4% and 60.2% for RD and IR, respectively, during the Warm test. Mean PPG pulse amplitudes decreased by 59.5% for IR and 46.1% for RD in the cold test when compared to baseline, but improved by 70.1% for IR and 59.0% for RD in the warm test. This improvement of up to 4x in signal quality during the warm condition was associated with a closer match (median difference of 1.5%) between the SpO(2) values estimated by the PO system and a commercial pulse oximeter. The differences measured in RMS and mean amplitudes for the three tests were statistically significant (p < 0.001). Overall, warm temperatures significantly improve PPG signal quality and SpO(2) estimation accuracy. Sensor site temperature is recommended to be maintained near 33 degrees C for reliable transmittance pulse oximetry. (C) 2015 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available