Catheter Treatment of Ventricular Tachycardia: A Reference-Less Pace-Mapping Method to Identify Ablation Targets

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 66, Issue 11, Pages 3278-3287

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2019.2903631

Keywords

Arrhythmia; radiofrequency catheter ablation; cardiac interventional electrophysiology; electrocardiography

Funding

  1. French Investments for the Future program [ANR-15-RHU-0004]
  2. INSERM
  3. Region Lorraine
  4. FEDER
  5. CPER 2007-2013

Ask authors/readers for more resources

Objective: A novel method is developed to identify ablation targets for the catheter treatment of ventricular tachycardia (VT). Methods: The method is based on pace-mapping, which is a validated technique to determine the catheter ablation targets. Conventionally, it consists of stimulating the heart ventricle from various sites and comparing the resulting activation pathways to that of a clinical VT by the analysis of surface electrocardiograms (ECG). In this paper, a novel pace-mapping method is presented, which does not require a reference ECG recording of the VT. A three-dimensional correlation gradient map is reconstructed by semiautomatic analysis of ECG morphological changes within the network of pace-mapping sites. In these maps, abnormal points are identified by high correlation gradient values (i.e., corresponding to slow propagation of the electric influx, as in the core of the reentrant VT circuit). The relation between the conventional and reference-less method is described theoretically and evaluated in a retrospective study including 24 VT ablation procedures. Results: The reference-less method was able to identify normal points with a high accuracy (negative predictive value: NPV = 97%), and to detect more abnormal points, as predicted by the theory. Correlation gradients computed by the proposed method were significantly higher in ablation zones than in other zones of the ventricle (p < 10(-12)), indicating excellent prediction of the ablation targets. Significance: The reference-less method might either be used in complement of the conventional method or to treat patients in whom VT cannot be induced during the intervention.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available