4.7 Article

Numerical simulation of the simultaneous removal of particulate matter in a wet flue gas desulfurization system

Journal

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
Volume 27, Issue 2, Pages 1598-1607

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-019-06773-9

Keywords

Simultaneous removal; PMs; Numerical simulation; Coal-fired power plant

Funding

  1. National key research and development program of China [2017YFB0603205]
  2. National Natural Science Foundation of China [U1609212, 51621005]

Ask authors/readers for more resources

The particulate matter (PM) could be simultaneously removed during the wet flue gas desulfurization (WFGD) process. To analyze the underlying mechanism and removal efficiency, the PM removal process in a desulfurization system was numerically simulated based on the population balance model and general dynamics equation in this study. The equation was solved using the fixed-step Monte Carlo method to determine the PM removal characteristics under different working conditions (such as spray intensity, velocity of the flue gas, and layers of slurry spray). When the flue gas velocity decreased from 7 to 3 m/s, the removal efficiency increased from 90.93 to 93.52%, and when the mean geometric droplet size decreased from 3 to 1 mm, the removal efficiency increased from 67.18 to 99.14%. Besides, large diameter PM was more easily removed by the desulfurization system. Thus, the numerical simulation method was proven to be feasible by comparing these results with field measurements of a WFGD system in a coal-fired power plant.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available